personal scheduler Hamburg 2013 - Main Site Press Release 2013 Call for Abstracts General Information Programme Overview Letter from the President Keynote Lectures Main Sessions NEW - Free Paper Session Instructional Courses World Retina Day Retinal Detachment Course Uveitis Course Other Symposia Surgical Skills Training Courses
hamburg banner

Excellent visual outcome of magnetic intraocular foreign body removal in selected cases: a safe and simple procedure

Session Details

Session Title: Quick Fire Free Paper Session 01

Session Date/Time: Thursday 26/09/2013 | 08:30-10:30

Paper Time: 09:25

Venue: Hall G1 (Level 2)

First Author: M.Khalife LEBANON

Co Author(s):    M. Mosavee   O. Tabrizi           

Abstract Details

Purpose:

To report 2 cases of IOFB floating in the vitreous using magnetic device without pars plana vitrectomy

Setting:

2 cases of IOFB floating in the vitreous using magnetic device to be reported

Methods:

A 4 mm long pars plana sclerotomy tangential to the limbus was created at site of the FB. Magnet was placed and FB removed Wound vitrectomy was done before and after FB removal

Results:

After 3 months patients had a BCVA of 20/20 and 20/25 respectively. In selected cases that the FB is just close to the eye wall and not attached or imbedded in retina, and also if it’s position is anterior enough so that it is accessible with magnet at pars plana

Conclusions:

IOFB removal using magnet can be considered as a safe procedure